; ;====================================================== ; GSD for Profi-EIM ; Date : 10/17/01 km ; Date : 11/06/02 jh ; Date : 12/06/02 jh ; Date : April 14, 2014 CV - Firmware 5.32.4.8 or newer ; ; DO NOT USE with prior firmware. ; ; - Updated parameter descriptions, added support for new byte-swap parameter. ; - Added Modules to support consistency over whole data length. ; - Added slot definitions to automatically populate slots in host software. ; - Updated general keywords to new values. ; ; Copyright Moog Animatics 2014 ;====================================================== ; #Profibus_DP ;====================================================== ;=== General Keywords ;====================================================== GSD_Revision = 3 Vendor_Name = "Animatics Corporation" Model_Name = "SmartMotor5" Info_Text = "Moog Animatics Class 5 Smartmotor. Requires SmartMotor firmware 5.x.4.8 or newer ONLY!" Revision = "1.0" Revision_Number = 1 Ident_Number = 0x070C Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "CL5_VPC3+S_1.0" Software_Release = "CL5_4.8" Redundancy = 0 Repeater_Ctrl_Sig = 2 24V_Pins = 0 Implementation_Type = "VPC3+S" ;====================================================== ;=== Supported Baud Rates and MaxTsdr values ;====================================================== 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_45.45 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 200 MaxTsdr_6M = 200 MaxTsdr_12M = 250 ;====================================================== ;=== Slave specific data ;====================================================== Slave_Family = 0@Animatics@SmartMotor Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Auto_Baud_supp = 1 Set_Slave_Add_supp = 0 Min_Slave_Intervall = 10 Modular_Station = 1 Max_Module = 2 ;User_Prm_Data_Len = 6 Max_Input_Len = 128 Max_Output_Len = 128 Max_Data_Len = 256 Max_Diag_Data_Len = 48 Max_User_Prm_Data_Len = 6 DPV1_Slave = 0 Fail_Safe = 0 Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x00,0x00,0x00,0x00 ; The first 3 parameter values above are for DPV1, ; which is not supported at this time. Therefore, leave as 0. ; ; Const bytes: ; [0] Spec_User_Prm_Byte/DPV1_Status_1 (DPV1 not supported at this time) ; [1] DPV1_Status_2 (DPV1 not supported at this time) ; [2] DPV1_Status_3 (DPV1 not supported at this time) ; [3] User_Prm_Data: Supports byte order swapping,other bits reserved. ; [4] User_Prm_Data: reserved. ; [5] User_Prm_Data: reserved. PrmText=3 ; Byte order examples: MSB=4, LSB=1. i.e. 4321 for big-endian format. ; 32-bit 16-bit Text(0)="big-endian (default)" ; 4321 21 (default) Byte order of most significant byte first in all 16 and 32-bit data fields within Modules. Text(1)="swap words only" ; 2143 21 Swaps the word (16-bit) order in the 32-bit fields: Measured position, Command data Value, Response data value. Text(2)="swap bytes only" ; 3412 12 Swap the bytes only within each 16 or 32-bit data field. Text(3)="little-endian" ; 1234 12 Byte order of least significant byte first in all 16 and 32-bit data fields within Modules. EndPrmText ExtUserPrmData=3 "Byte order" BitArea(0-1) 0 0-3 Prm_Text_Ref=3 EndExtUserPrmData Ext_User_Prm_Data_Ref(3) = 3 ;====================================================== ;=== Module Configuration ;====================================================== Module = "7 Words In, consistent" 0xD6 ; This specifies consistency over the whole data length. ; Requires firmware 5.32.4.8 or newer. 1 EndModule Module = "3 Words Out, consistent" 0xE2 ; This specifies consistency over the whole data length. ; Requires firmware 5.32.4.8 or newer. 2 EndModule SlotDefinition Slot(1) = "Slot 1" 1 1 Slot(2) = "Slot 2" 2 2 EndSlotDefinition