<?xml version="1.0" encoding="iso-8859-1"?>
<ISO15745Profile xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.profibus.com/GSDML/2003/11/DeviceProfile ..\xsd\GSDML-DeviceProfile-V2.3.xsd">
  <ProfileHeader>
    <ProfileIdentification>PROFINET Device Profile</ProfileIdentification>
    <ProfileRevision>1.00</ProfileRevision>
    <ProfileName>Device Profile for PROFINET Devices</ProfileName>
    <ProfileSource>PROFIBUS Nutzerorganisation e. V. (PNO)</ProfileSource>
    <ProfileClassID>Device</ProfileClassID>
    <ISO15745Reference>
      <ISO15745Part>4</ISO15745Part>
      <ISO15745Edition>1</ISO15745Edition>
      <ProfileTechnology>GSDML</ProfileTechnology>
    </ISO15745Reference>
  </ProfileHeader>
  <ProfileBody>
    <DeviceIdentity DeviceID="0x0001" VendorID="0x020F">
      <InfoText TextId="DeviceDescription_InfoText" />
      <VendorName Value="MOOG Animatics" />
    </DeviceIdentity>	
    <DeviceFunction>
      <Family MainFamily="Drives" ProductFamily="SmartMotor" />
    </DeviceFunction>
    <ApplicationProcess>
      <DeviceAccessPointList>
	  
        <DeviceAccessPointItem DNS_CompatibleName="SMC6DEV01" FixedInSlots="0" ID="DIM 1" ImplementationType="netX" MinDeviceInterval="64" ModuleIdentNumber="0x00001001" ObjectUUID_LocalIndex="1" PhysicalSlots="0..2" DeviceAccessSupported="true" PNIO_Version="V2.3">
          <ModuleInfo>
            <Name TextId="devName" />
            <InfoText TextId="DIM 1_InfoText" />
            <VendorName Value="MOOG Animatics" />
            <OrderNumber Value="ST23306M-SGG1" />
            <HardwareRelease Value="3" />
            <SoftwareRelease Value="6.0.0" />
          </ModuleInfo>
          <SubslotList>
            <SubslotItem SubslotNumber="32768" TextId="X1" />
            <SubslotItem SubslotNumber="32769" TextId="X1P1" />
            <SubslotItem SubslotNumber="32770" TextId="X1P2" />
          </SubslotList>
          <IOConfigData MaxInputLength="128" MaxOutputLength="128" />
          <UseableModules>
            <ModuleItemRef ModuleItemTarget="14byteinput" UsedInSlots="1" AllowedInSlots="1" />
            <ModuleItemRef ModuleItemTarget="56byteinput" AllowedInSlots="1" />
            <ModuleItemRef ModuleItemTarget="6byteoutput" UsedInSlots="2" />
            <ModuleItemRef ModuleItemTarget="24byteoutput" AllowedInSlots="2" />
          </UseableModules>
           <VirtualSubmoduleList>
            <VirtualSubmoduleItem ID="DIM 1" SubmoduleIdentNumber="0x00001000" Writeable_IM_Records="1 2 3 4">
              <IOData IOCS_Length="1" IOPS_Length="1" />
              <ModuleInfo CategoryRef="DAP Module">
                <Name TextId="devName" />
                <InfoText TextId="DIM 1_InfoText" />
              </ModuleInfo>
            </VirtualSubmoduleItem>
          </VirtualSubmoduleList>
          <SystemDefinedSubmoduleList>
            <InterfaceSubmoduleItem ID="IDS_1I" NetworkComponentDiagnosisSupported="true" SubmoduleIdentNumber="0x00001001" SubslotNumber="32768" SupportedMibs="MIB2" SupportedProtocols="SNMP;LLDP" SupportedRT_Classes="RT_CLASS_1" TextId="PN-IO">
              <ApplicationRelations>
                <TimingProperties ReductionRatio="1 2 4 8 16 32 64 128 256 512" SendClock="32 64 128" />
              </ApplicationRelations>
            </InterfaceSubmoduleItem>
            <PortSubmoduleItem ID="IDS_1P1" LinkStateDiagnosisCapability="Up+Down" MAUTypes="16" SubmoduleIdentNumber="0x00001002" SubslotNumber="32769" TextId="Port1" />
            <PortSubmoduleItem ID="IDS_1P2" LinkStateDiagnosisCapability="Up+Down" MAUTypes="16" SubmoduleIdentNumber="0x00001003" SubslotNumber="32770" TextId="Port2" />
          </SystemDefinedSubmoduleList>
          <Graphics>
            <GraphicItemRef GraphicItemTarget="1" Type="DeviceSymbol" />
          </Graphics>
        </DeviceAccessPointItem>
		
        <DeviceAccessPointItem DNS_CompatibleName="SMC6DEV01" FixedInSlots="0" ID="DIM 2" ImplementationType="netX" MinDeviceInterval="64" ModuleIdentNumber="0x00001011" ObjectUUID_LocalIndex="1" PhysicalSlots="0..2" DeviceAccessSupported="true" PNIO_Version="V2.3">
          <ModuleInfo>
            <Name TextId="devName2" />
            <InfoText TextId="DIM 2_InfoText" />
            <VendorName Value="MOOG Animatics" />
            <OrderNumber Value="CL6D" />
            <HardwareRelease Value="3" />
            <SoftwareRelease Value="V6.?.?" />
          </ModuleInfo>
          <SubslotList>
            <SubslotItem SubslotNumber="32768" TextId="X1" />
            <SubslotItem SubslotNumber="32769" TextId="X1P1" />
            <SubslotItem SubslotNumber="32770" TextId="X1P2" />
          </SubslotList>
          <IOConfigData MaxInputLength="128" MaxOutputLength="128" />
          <UseableModules>
            <ModuleItemRef ModuleItemTarget="14byteinput" UsedInSlots="1" AllowedInSlots="1" />
            <ModuleItemRef ModuleItemTarget="56byteinput" AllowedInSlots="1" />
            <ModuleItemRef ModuleItemTarget="6byteoutput" UsedInSlots="2" />
            <ModuleItemRef ModuleItemTarget="24byteoutput" AllowedInSlots="2" />
          </UseableModules>
           <VirtualSubmoduleList>
            <VirtualSubmoduleItem ID="DIM 2" SubmoduleIdentNumber="0x00001010" Writeable_IM_Records="1 2 3 4">
              <IOData IOCS_Length="1" IOPS_Length="1" />
              <ModuleInfo CategoryRef="DAP Module">
                <Name TextId="devName2" />
                <InfoText TextId="DIM 2_InfoText" />
              </ModuleInfo>
            </VirtualSubmoduleItem>
          </VirtualSubmoduleList>
          <SystemDefinedSubmoduleList>
            <InterfaceSubmoduleItem ID="IDS_11I" NetworkComponentDiagnosisSupported="true" SubmoduleIdentNumber="0x00001011" SubslotNumber="32768" SupportedMibs="MIB2" SupportedProtocols="SNMP;LLDP" SupportedRT_Classes="RT_CLASS_1" TextId="PN-IO">
              <ApplicationRelations>
                <TimingProperties ReductionRatio="1 2 4 8 16 32 64 128 256 512" SendClock="32 64 128" />
              </ApplicationRelations>
            </InterfaceSubmoduleItem>
            <PortSubmoduleItem ID="IDS_11P1" LinkStateDiagnosisCapability="Up+Down" MAUTypes="16" SubmoduleIdentNumber="0x00001012" SubslotNumber="32769" TextId="Port1" />
            <PortSubmoduleItem ID="IDS_11P2" LinkStateDiagnosisCapability="Up+Down" MAUTypes="16" SubmoduleIdentNumber="0x00001013" SubslotNumber="32770" TextId="Port2" />
          </SystemDefinedSubmoduleList>
          <Graphics>
            <GraphicItemRef GraphicItemTarget="2" Type="DeviceSymbol" />
          </Graphics>
        </DeviceAccessPointItem>
		
      </DeviceAccessPointList>
	  
      <ModuleList>
        <ModuleItem ID="14byteinput" ModuleIdentNumber="0x00000002">
          <ModuleInfo CategoryRef="Input Module">
            <Name TextId="Module_14byteinput_Name" />
            <InfoText TextId="Module_14byteinput_InfoText" />
          </ModuleInfo>
          <VirtualSubmoduleList>
            <VirtualSubmoduleItem FixedInSubslots="1" ID="14byteinputsub" SubmoduleIdentNumber="0x00000001">
				<IOData>
					<Input>
					  <DataItem DataType="OctetString" Length="14" TextId="DataItem_14byteinput_inputdata_0_Name" />
					</Input>
				</IOData>
				<RecordDataList>
					<ParameterRecordDataItem Index="3" Length="1">
						<Name TextId="GeneralParam"/>
						<Ref ValueItemTarget="ByteOrderValueChoices" DataType="BitArea" ByteOffset="0" BitOffset="0" BitLength="2"
						DefaultValue="0" AllowedValues="0..3" TextId="ByteOrderRef"/>
					</ParameterRecordDataItem>
				</RecordDataList>
              <ModuleInfo>
                <Name TextId="Submodule_14byteinput_Name" />
                <InfoText TextId="Submodule_14byteinput_InfoText" />
              </ModuleInfo>
            </VirtualSubmoduleItem>
          </VirtualSubmoduleList>
        </ModuleItem>
        <ModuleItem ID="56byteinput" ModuleIdentNumber="0x00000004">
          <ModuleInfo CategoryRef="Input Module">
            <Name TextId="Module_56byteinput_Name" />
            <InfoText TextId="Module_56byteinput_InfoText" />
          </ModuleInfo>
          <VirtualSubmoduleList>
            <VirtualSubmoduleItem ID="56byteinputsub" Max_iParameterSize="8" SubmoduleIdentNumber="0x00000003">
				<IOData>
					<Input>
					  <DataItem DataType="OctetString" Length="56" TextId="DataItem_56byteinput_inputdata_0_Name" />
					</Input>
				</IOData>
				<RecordDataList>
					<ParameterRecordDataItem Index="3" Length="1">
						<Name TextId="GeneralParam"/>
						<Ref ValueItemTarget="ByteOrderValueChoices" DataType="BitArea" ByteOffset="0" BitOffset="0" BitLength="2"
						DefaultValue="0" AllowedValues="0..3" TextId="ByteOrderRef"/>
					</ParameterRecordDataItem>
				</RecordDataList>			  
              <ModuleInfo>
                <Name TextId="Submodule_56byteinput_Name" />
                <InfoText TextId="Submodule_56byteinput_InfoText" />
              </ModuleInfo>
            </VirtualSubmoduleItem>
          </VirtualSubmoduleList>
        </ModuleItem>
        <ModuleItem ID="6byteoutput" ModuleIdentNumber="0x00000003">
          <ModuleInfo CategoryRef="Output Module">
            <Name TextId="Module_6byteoutput_Name" />
            <InfoText TextId="Module_6byteoutput_InfoText" />
          </ModuleInfo>
          <VirtualSubmoduleList>
            <VirtualSubmoduleItem ID="6byteoutputsub" SubmoduleIdentNumber="0x00000002">
				<IOData>
					<Output>
					  <DataItem DataType="OctetString" Length="6" TextId="DataItem_6byteoutput_outputdata_0_Name" />
					</Output>
				</IOData>
				<RecordDataList>
					<ParameterRecordDataItem Index="3" Length="1">
						<Name TextId="GeneralParam"/>
						<Ref ValueItemTarget="ByteOrderValueChoices" DataType="BitArea" ByteOffset="0" BitOffset="0" BitLength="2"
						DefaultValue="0" AllowedValues="0..3" TextId="ByteOrderRef"/>
					</ParameterRecordDataItem>
				</RecordDataList>
              <ModuleInfo>
                <Name TextId="Submodule_6byteoutput_Name" />
                <InfoText TextId="Submodule_6byteoutput_InfoText" />
              </ModuleInfo>
            </VirtualSubmoduleItem>
          </VirtualSubmoduleList>
        </ModuleItem>
        <ModuleItem ID="24byteoutput" ModuleIdentNumber="0x00000005">
          <ModuleInfo CategoryRef="Output Module">
            <Name TextId="Module_24byteoutput_Name" />
            <InfoText TextId="Module_24byteoutput_InfoText" />
          </ModuleInfo>
          <VirtualSubmoduleList>
            <VirtualSubmoduleItem ID="24byteoutputsub" SubmoduleIdentNumber="0x00000004">
				<IOData>
					<Output>
					  <DataItem DataType="OctetString" Length="24" TextId="DataItem_24byteoutput_outputdata_0_Name" />
					</Output>
				</IOData>
				<RecordDataList>
					<ParameterRecordDataItem Index="3" Length="1">
						<Name TextId="GeneralParam"/>
						<Ref ValueItemTarget="ByteOrderValueChoices" DataType="BitArea" ByteOffset="0" BitOffset="0" BitLength="2"
						DefaultValue="0" AllowedValues="0..3" TextId="ByteOrderRef"/>
					</ParameterRecordDataItem>
				</RecordDataList>
              <ModuleInfo>
                <Name TextId="Submodule_24byteoutput_Name" />
                <InfoText TextId="Submodule_24byteoutput_InfoText" />
              </ModuleInfo>
            </VirtualSubmoduleItem>
          </VirtualSubmoduleList>
        </ModuleItem>
		</ModuleList>
		<ValueList>
			<ValueItem ID="ByteOrderValueChoices">
				<Help TextId="ChooseByteOrder"/>
				<Assignments>
					<Assign Content="0" TextId="byteorder_0"/>
					<Assign Content="1" TextId="byteorder_1"/>
					<Assign Content="2" TextId="byteorder_2"/>
					<Assign Content="3" TextId="byteorder_3"/>
				</Assignments>
			</ValueItem>
		</ValueList>			
		<GraphicsList>
			<GraphicItem GraphicFile="GSDML-020F-0001-SMC6DEV01" ID="1" />
			<GraphicItem GraphicFile="GSDML-020F-0001-SMC6DEV01_ANI" ID="2" />			
		</GraphicsList>
      <CategoryList>
        <CategoryItem ID="DAP Module" TextId="DAP Module_CategoryName" />
        <CategoryItem ID="Input Module" TextId="Input Module_CategoryName" />
        <CategoryItem ID="Output Module" TextId="Output Module_CategoryName" />
      </CategoryList>
      <ExternalTextList>
        <PrimaryLanguage>
          <Text TextId="DAP Module_CategoryName" Value="Device Access Point Modules" />
          <Text TextId="DIM 1_InfoText" Value="OEM Schmid Integrated Motor, Netx50 LFW V3.4.x I &amp; M 1-4, RT Communication." />
          <Text TextId="DIM 2_InfoText" Value="Smartmotor Class 6 D series Profinet NIC" />		  
          <Text TextId="DataItem_14byteinput_inputdata_0_Name" Value="Inputs" />
          <Text TextId="DataItem_56byteinput_inputdata_0_Name" Value="Inputs" />
          <Text TextId="DataItem_6byteoutput_outputdata_0_Name" Value="Outputs" />
          <Text TextId="DataItem_24byteoutput_outputdata_0_Name" Value="Outputs" />
          <Text TextId="DeviceDescription_InfoText" Value="PROFINET IO-Device" />
          <Text TextId="Input Module_CategoryName" Value="Input Modules" />
          <Text TextId="Module_14byteinput_InfoText" Value="14 Bytes Input Module" />
          <Text TextId="Module_14byteinput_Name" Value="14 Bytes Input" />
          <Text TextId="Module_56byteinput_InfoText" Value="56 Bytes Input Module" />
          <Text TextId="Module_56byteinput_Name" Value="56 Bytes Input" />
          <Text TextId="Module_6byteoutput_InfoText" Value="6 Bytes Output Module" />
          <Text TextId="Module_6byteoutput_Name" Value="6 Bytes Output" />
          <Text TextId="Module_24byteoutput_InfoText" Value="24 Bytes Output Module" />
          <Text TextId="Module_24byteoutput_Name" Value="24 Bytes Output" />
          <Text TextId="devName" Value="ST23306M-SGG1" />
          <Text TextId="devName2" Value="CL6D" />		  
          <Text TextId="Output Module_CategoryName" Value="Output Modules" />
          <Text TextId="PN-IO" Value="PN-IO" />
          <Text TextId="Port1" Value="Port 1" />
          <Text TextId="Port2" Value="Port 2" />
          <Text TextId="Submodule_14byteinput_InfoText" Value="14 Bytes Input Submodule" />
          <Text TextId="Submodule_14byteinput_Name" Value="14 Bytes Input" />
          <Text TextId="Submodule_14byteinput_diag_InfoText" Value="14 Bytes Input Submodule" />
          <Text TextId="Submodule_14byteinput_diag_Name" Value="14 Bytes Input" />
          <Text TextId="Submodule_56byteinput_InfoText" Value="56 Bytes Input Submodule" />
          <Text TextId="Submodule_56byteinput_Name" Value="56 Bytes Input" />
          <Text TextId="Submodule_6byteoutput_InfoText" Value="6 Bytes Output Submodule" />
          <Text TextId="Submodule_6byteoutput_Name" Value="6 Bytes Output" />
          <Text TextId="Submodule_24byteoutput_InfoText" Value="24 Bytes Output Submodule" />
          <Text TextId="Submodule_24byteoutput_Name" Value="24 Bytes Output" />
          <Text TextId="X1" Value="X1" />
          <Text TextId="X1P1" Value="X1 P1" />
          <Text TextId="X1P2" Value="X1 P2" />
		  <Text TextId="GeneralParam" Value="General parmaters" />
		  <Text TextId="ByteOrderRef" Value="Byte order" />
		  <Text TextId="ChooseByteOrder" Value="Choose byte order" />
		  
		  <Text TextId="byteorder_0" Value="big-endian (default)" />
		  <Text TextId="byteorder_1" Value="swap words only" />
		  <Text TextId="byteorder_2" Value="swap bytes only" />
		  <Text TextId="byteorder_3" Value="little-endian" />
        </PrimaryLanguage>
        <Language xml:lang="de">
          <Text TextId="DAP Module_CategoryName" Value="Device Access Point Module" />
          <Text TextId="DIM 1_InfoText" Value="OEM Schmid Integrated Motor, Netx50 LFW V3.4.x I &amp; M 1-4, RT Betrieb." />
          <Text TextId="DIM 2_InfoText" Value="Smartmotor Class 6 D series Profinet NIC" />		  
          <Text TextId="DataItem_14byteinput_inputdata_0_Name" Value="Eingänge" />
          <Text TextId="DataItem_56byteinput_inputdata_0_Name" Value="Eingänge" />
          <Text TextId="DataItem_6byteoutput_outputdata_0_Name" Value="Ausgänge" />
          <Text TextId="DataItem_24byteoutput_outputdata_0_Name" Value="Ausgänge" />
          <Text TextId="DeviceDescription_InfoText" Value="PROFINET IO-Device" />
          <Text TextId="Input Module_CategoryName" Value="Eingangsmodule" />
          <Text TextId="Module_14byteinput_InfoText" Value="14 Byte Eingangsmodul" />
          <Text TextId="Module_14byteinput_Name" Value="14 Byte Eingang" />
          <Text TextId="Module_14byteinput_diag_InfoText" Value="14 Byte Eingangsmodul" />
          <Text TextId="Module_14byteinput_diag_Name" Value="14 Byte Eingang" />
          <Text TextId="Module_56byteinput_InfoText" Value="56 Byte Eingangsmodul" />
          <Text TextId="Module_56byteinput_Name" Value="56 Byte Eingang" />
          <Text TextId="Module_6byteoutput_InfoText" Value="6 Byte Ausgangsmodul" />
          <Text TextId="Module_6byteoutput_Name" Value="6 Byte Ausgang" />
          <Text TextId="Module_24byteoutput_InfoText" Value="24 Byte Ausgangsmodul" />
          <Text TextId="Module_24byteoutput_Name" Value="24 Byte Ausgang" />
          <Text TextId="devName" Value="ST23306M-SGG1" />
          <Text TextId="devName2" Value="CL6D" />		  
          <Text TextId="Output Module_CategoryName" Value="Ausgangsmodule" />
          <Text TextId="PN-IO" Value="PN-IO" />
          <Text TextId="Port1" Value="Port 1" />
          <Text TextId="Port2" Value="Port 2" />
          <Text TextId="Submodule_14byteinput_InfoText" Value="14 Byte Eingangssubmodul" />
          <Text TextId="Submodule_14byteinput_Name" Value="14 Byte Eingang" />
          <Text TextId="Submodule_56byteinput_InfoText" Value="56 Byte Eingangssubmodul" />
          <Text TextId="Submodule_56byteinput_Name" Value="56 Byte Eingang" />
          <Text TextId="Submodule_6byteoutput_InfoText" Value="6 Byte Ausgangssubmodul" />
          <Text TextId="Submodule_6byteoutput_Name" Value="6 Byte Ausgang" />
          <Text TextId="Submodule_24byteoutput_InfoText" Value="24 Byte Ausgangssubmodul" />
          <Text TextId="Submodule_24byteoutput_Name" Value="24 Byte Ausgang" />
          <Text TextId="X1" Value="X1" />
          <Text TextId="X1P1" Value="X1 P1" />
          <Text TextId="X1P2" Value="X1 P2" />
        </Language>
      </ExternalTextList>
    </ApplicationProcess>
  </ProfileBody>
</ISO15745Profile>